FDA MedWatch – Accusure Insulin Syringes (Qualitest Pharmaceuticals) – Recall

Qualitest Pharmaceuticals and FDA notified healthcare professionals of a nationwide recall of Accusure Insulin Syringes. All syringes, regardless of lot number, are subject to this recall. These syringes were distributed between January 2002 and October 2009 to wholesale and retail pharmacies nationwide (including Puerto Rico). The syringes in these lots may have needles which detach from the syringe. If the needle becomes detached from the syringe during use, it can become stuck in the insulin vial, push back into to the syringe, or remain in the skin after injection. Consumers who have any Accusure insulin syringes should stop using them and contact Qualitest at 1-800-444-4011 for reimbursement.

CLICK HERE to read the complete MedWatch 2009 Safety summary, including a link to the firm’s press release and previous August 2009 recall.

FDA MedWatch – Peramivir IV

FDA notified healthcare professionals that, in response to a request from the U.S. Centers for Disease Control and Prevention, it has issued an emergency use authorization (EUA) for the investigational antiviral drug peramivir intravenous in certain adult and pediatric patients with confirmed or suspected 2009 H1N1 influenza infection who are admitted to a hospital. IV peramivir is authorized only for hospitalized adult and pediatric patients for whom therapy with an IV drug is clinically appropriate, based on one or more of the following: 1] the patient is not responding to either oral or inhaled antiviral therapy, 2] when drug delivery by a route other than an intravenous route is not expected to be dependable or feasible, or 3] for adults only, when the clinician judges IV therapy is appropriate due to other circumstances.

Given there are limited safety data on peramivir, mandatory reporting requirements are important to defining the safety profile of this unapproved drug. As part of the conditions of the EUA, health care providers (or designee) must report adverse events and all medication errors associated with peramivir to FDA’s MedWatch program within 7 calendar days from the onset of the adverse event. Additionally, healthcare providers (or designee) must conduct follow-up requested by FDA or CDC related to peramivir adverse event or medication error reports submitted to FDA.

CLICK HERE to read the complete MedWatch 2009 Safety summary, including links to the Information for Healthcare Professionals and FDA News Release.

FDA MedWatch – Rituxan (rituximab) – PML

Genentech and FDA notified healthcare professionals about a third case of progressive multifocal leukoencephalopathy [PML], the first case of PML in a patient with rheumatoid arthritis [RA] treated with Rituxan who has not previously received treatment with a TNF antagonist. Information to date suggests that patients with RA who receive Rituxan have an increased risk of PML.

Physicians should consider PML in any patient being treated with Rituxan who presents with new onset neurologic manifestations. Consultation with a neurologist, brain MRI, and lumbar puncture should be considered as clinically indicated.

CLICK HERE to read the complete MedWatch 2009 Safety summary, including a link to the Dear Healthcare Professional letter and prescribing information.

FDA MedWatch – Ketorolac Tromethamine Injection, USP 30 mg/mL; 1mL and 2mL Single Dose Vials Recall

American Regent and FDA notified healthcare professionals of a voluntary recall of all lots of Ketorolac Tromethamine Injection, USP 30 mg/mL, including NDC# 0517-0801-25 [30 mg/mL 1mL Single Dose Vial] and NDC# 0517-0902-25 [30 mg/mL 2mL Single Dose Vial (60 mg/2mL)]. There is a potential for particulate matter in conjunction with crystallization that may be present in the product, which may result in adverse events such as obstruction of blood vessels which can induce pulmonary emboli or thrombosis, activate platelets and/or neutrophils to induce anaphylactic reactions. Other adverse effects associated with the injection of particulate matter include foreign body granulomas, and local irritation at the injection site.

This recall does not include other concentrations of American Regent Ketorolac Tromethamine Injection. The product was distributed to wholesalers and distributors nationwide. Hospitals, surgi-centers, clinics and other healthcare facilities should not use any American Regent Ketorolac Tromethamine Injection, USP Injection 30 mg/mL for patient care and should immediately quarantine any product for return.

CLICK HERE to read the MedWatch safety summary, including a link to the firm press release.

FDA MedWatch – Medical Device Power Cords Safety Investigation: Initial Communication

FDA is investigating whether certain types of power cords used with medical devices may be defective. Two medical device manufacturers (Hospira, Inc. and Abbott Nutrition) have sent FDA 122 reports of sparking, charring, and fires from the power cords used with their devices. The companies’ investigations of these reports determined that the power cord’s prongs may crack and fail at/or inside the plug. The potential risks from this power cord failure include electrical shock, delay in setup and therapy, interruption of therapy, device failure, and fires. Depending on the device and therapy, these failures may potentially lead to serious adverse health consequences, including death.

All the reports received so far from Hospira and Abbott have involved AC power cords with a black plastic bridge manufactured by the Electri-cord Manufacturing Company. FDA is aware that Electri-cord has supplied the affected power cords to other medical device manufacturers. The agency is now attempting to determine which devices may be equipped with these cords.

FDA recommends that all users of medical devices, either in healthcare facilities or in the home, closely monitor the wear and tear on the electric cords used to power these devices. This vigilance is especially important in oxygen rich environments, in which electrical sparking and arcing may trigger a fire.

CLICK HERE to read the MedWatch safety summary, including a link to the FDA Initial Communication.

FDA MedWatch – September 2009 Drug Safety Labeling Changes

The MedWatch September 2009 Drug Safety Labeling Changes posting includes 36 drug products with safety labeling changes to the following sections: BOXED WARNING, CONTRAINDICATIONS, WARNINGS, PRECAUTIONS, ADVERSE REACTIONS, PATIENT PACKAGE INSERT, and MEDICATION GUIDE.

The “Summary Page” provides a listing of drug names and safety labeling sections revised: http://www.fda.gov/Safety/MedWatch/SafetyInformation/ucm183107.htm

Clicking on a drug product name in the Summary View will take you to the “detailed view” page, which identifies safety labeling sections and subsections revised, along with a brief summary of new or modified safety information to the BOXED WARNING, CONTRAINDICATIONS, and/or WARNINGS sections.

The following drugs had modifications to the BOXED WARNING, CONTRAINDICATIONS, and WARNINGS sections:

AndroGel (testosterone gel), Rapamune (sirolimus), Testim (testosterone gel), Cordarone (amiodarone HCl), Flector Patch (diclofenac epolamine), Intelence (etravirine), Kayexalate (sodium polystyrene sulfonate), Lexiva (fosamprenavir calcium), Neoral (cyclosporine capsules, modified), Ortho Evra (norelgestromin/ethinyl estradiol) transdermal system, Pre-Pen (benzylpenicilloyl polylysine), Sustiva (efavirenz), Ultracet (tramadol HCl/acetaminophen), Ultram (tramadol hydrochloride), Voltaren Gel (diclofenac sodium), Zolinza (vorinostat).

FDA MedWatch – Dexferrum (iron dextran injection) – Labeling change

American Regent and FDA notified healthcare professionals that anaphylactic-type reactions, including fatalities, have followed the parenteral administration of iron dextran injection. The Boxed Warning has been modified to recommend administering a test dose prior to the first therapeutic dose and observing for signs or symptoms of anaphylactic-type reactions during administration of Dexferrum. Fatal reactions have followed the test dose of iron dextran injection, even in situations where the test dose was tolerated. Patients with a history of drug allergy or multiple drug allergies may be at increased risk of anaphylactic-type reactions. It is recommended that resuscitation equipment and personnel trained in the detection and treatment of anaphylactic-type reactions be readily available during Dexferrum administration.

CLICK HERE to read the complete MedWatch 2009 Safety summary, including links to the Dear Healthcare professional letter and the revised prescribing information.

FDA MedWatch – Relenza (zanamivir) Inhalation Powder

GlaxoSmithKline (GSK) and FDA notified healthcare professionals of a report of the death of a patient with influenza who received Relenza (zanamivir) Inhalation Powder which was solubilized and administered by mechanical ventilation. Relenza (zanamivir) Inhalation Powder is not intended to be reconstituted in any liquid formulation and is not recommended for use in any nebulizer or mechanical ventilator.

GSK is aware that Relenza Inhalation Powder is being removed from its FDA-approved packaging and dissolved in various solutions for the purpose of nebulizing zanamivir for inhalation by patients with influenza who are unable to take oral medications or unable to inhale Relenza Inhalation Powder using the Diskhaler. Relenza or zanamivir for nebulization have not been approved by the FDA. The safety, effectiveness, and stability of zanamivir use by nebulization have not been established.

Relenza Inhalation Powder should only be used as directed in the prescribing information by using the Diskhaler device provided with the drug product. Relenza Inhalation Powder is a mixture of zanamivir active drug substance and lactose drug carrier. This formulation is not designed or intended to be administered by nebulization. There is a risk that the lactose sugar in this formulation can obstruct proper functioning of mechanical ventilator equipment.

CLICK HERE to read the MedWatch safety summary, including a link to the Dear Healthcare Professional Letter.

FDA MedWatch – CT Brain Perfusion Scans Safety Investigation: Initial Notification

FDA notified healthcare professionals that it has become aware of radiation overexposures during perfusion CT imaging performed to aid in the diagnosis of stroke at a particular facility, the patients receiving radiation doses that were approximately eight times the expected level. While this event involved a single kind of diagnostic test at one facility, the magnitude of these overdoses and their impact on the affected patients were significant. This situation may reflect more widespread problems with CT quality assurance programs and may not be isolated to this particular facility or this imaging procedure (CT brain perfusion). If patient doses are higher than the expected level, but not high enough to produce obvious signs of radiation injury, the problem may go undetected and unreported, putting patients at increased risk for long-term radiation effects.

FDA encourages every facility performing CT imaging to review its CT protocols and be aware of the dose indices normally displayed on the control panel. These indices include the volume computed tomography dose index and the dose-length product. For each protocol selected, and before scanning the patient, carefully monitor the dose indices displayed on the control panel. To prevent accidental overexposure, make sure that the values displayed reasonably correspond to the doses normally associated with the protocol. Confirm this again after the patient has been scanned. Patients should follow their doctor’s recommendations for receiving CT scans. While unnecessary radiation exposure should be avoided, a medically-needed CT scan has benefits that outweigh the radiation risks.

CLICK HERE to read the MedWatch safety summary, including a link to the FDA Initial Notification.

FDA MedWatch – Unomedical Manual Pulmonary Resuscitator – Recall

Unomedical and FDA notified healthcare professionals about the recall of the single-patient use Manual Pulmonary Resuscitator because of a malfunction which may impair the ability of the device to generate the positive pressure necessary to function properly and could potentially cause serious adverse health consequences or death. The recalled resuscitators were manufactured from July 2002 – March 2008 and the company set up a web page, http://www.unomedical.com/?pageid=H3160 with a list of affected lot numbers, guidance (diagram and photos) to allow customers to identify products subject to the recall in the event that the customer has already removed the primary product packaging, and instructions on what actions to take.

CLICK HERE to read the complete MedWatch 2009 Safety summary, including links to the firm’s press release and product photos.